What are the precautions for the installation and use of air showers and fog showers?
2025-04-29
What are the precautions for the installation and use of air showers and fog showers?
The installation and usage precautions of air showers and fog showers are different. The following is an introduction for you respectively:Air shower room
Installation Precautions
Site selection: It should be installed at the entrance of a clean room or clean area. The surrounding environment should be kept clean. It should be avoided to be installed in a dusty, damp, or corrosive gas place. The ground needs to be level to ensure the stable placement of the air shower.
Space requirements: The installation location of the air shower room should reserve sufficient space to facilitate the entry and exit of personnel and goods, as well as the maintenance and repair of the equipment. Generally speaking, at least 0.5 to 1 meter of space should be left around the air shower room.
Power connection: The air shower room needs to be connected to an appropriate power supply to ensure a stable voltage that meets the rated voltage requirements of the equipment. An independent power switch and leakage protection device should be equipped to ensure safety.
Installation and commissioning: During the installation process, operations must be carried out strictly according to the instructions to ensure that all components are installed firmly and connected tightly. After installation is completed, commissioning is required, including checking whether the fan is operating normally, whether the wind speed meets the requirements, and whether the nozzle Angle is appropriate, etc.
Precautions for Use
Personnel operation: Before entering the air shower room, personnel should clean up any debris on their bodies, close the door of the air shower room, and then start the air shower program. During the wind shower process, personnel should remain still, raise their hands, and turn 360 degrees to ensure that all parts of the body are exposed to the wind shower. After the air shower is over, you can leave the air shower room only when the door opens automatically or you hear the prompt sound.
Cargo handling: For cargo air showers, the goods should be evenly placed in the air shower room to avoid blocking the nozzles. The size and weight of the goods should be within the allowable range of the air shower room to avoid affecting the air shower effect or damaging the equipment.
Regular maintenance: By the maintenance and care requirements of the equipment, regularly clean the inner and outer surfaces of the air shower, replace the filters, and inspect the fans and electrical systems, etc. If any abnormal conditions are found in the equipment, such as a decrease in wind speed or an increase in noise, the machine should be stopped immediately for inspection. Only after the fault is eliminated can it be used again.
Safety Precautions: During the operation of the air shower, it is strictly prohibited to open the door or perform any other operations to avoid accidents. At the same time, it is necessary to ensure that the equipment is well grounded to prevent electric shock accidents.
Fog shower room
Installation Precautions
Environmental requirements: The fog shower room is suitable for installation in places with high cleanliness requirements, such as pharmaceutical workshops and laboratories. The installation environment should be dry and well-ventilated. The temperature and humidity should meet the operational requirements of the equipment. Generally, the temperature should be between 5 and 35℃, and the relative humidity should be between 30% and 80%.
Pipe connection: The atomization system of the fog shower room needs to be connected to an appropriate water source and compressed air source. The water source should be kept clean and free of impurities to avoid clogging the atomizing nozzles. The pressure and flow rate of compressed air should meet the requirements of the equipment. The connecting pipes should be well-sealed to prevent air leakage.
Electrical installation: When connecting the power supply, it is necessary to ensure that the voltage and frequency of the power supply are consistent with the rated parameters of the equipment. Reliable grounding devices should be installed to ensure the safe operation of the equipment. At the same time, by the control requirements of the fog shower room, the circuits of various sensors and controllers should be properly connected to ensure the normal operation of the equipment's automated functions.
Layout design: Based on the actual situation of the usage site, the layout of the fog shower room should be reasonably designed. The entry and exit channels for personnel and goods, as well as the coordinated placement with surrounding equipment, should be taken into consideration to ensure convenient operation and not affect the overall workflow.
Precautions for Use
Operating procedure: Before use, it is necessary to check whether all parameters of the equipment are set correctly, such as spray time, spray frequency, fan wind speed, etc. After personnel or goods enter the fog shower room, close the door and start the program. The equipment will perform spray and blow shower operations according to the preset parameters. During the operation, personnel should stand in the prescribed posture, and goods should be placed in the designated positions to ensure they can be fully exposed to fog and air.
Liquid management: Regularly check the liquid level of the liquid used in the fog shower room (such as deionized water, special cleaning liquid, etc.), and replenish the liquid in time to avoid affecting the atomization effect due to low liquid level. At the same time, the liquid should be replaced regularly to prevent it from deteriorating and breeding bacteria.
Equipment cleaning: After each use, the debris and residual liquid in the mist shower chamber should be cleared in time. Regularly clean and maintain components such as atomizing nozzles, fans, and filters to prevent clogging and contamination. If the nozzle is found to be clogged, it should be disassembled, cleaned, or replaced in time.
Safety Precautions: The liquid used in the fog shower room may have certain corrosiveness or irritability. During operation, personal protection should be noted to avoid contact with the liquid with the skin and eyes. In case of accidental contact, rinse immediately with plenty of water and seek medical attention promptly. In addition, when the equipment is in operation, it is strictly forbidden to open the cover of the atomization system or perform other dangerous operations to avoid accidents.